Rosemount 8711
Specifications
Accuracy | Up to 0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.25% over 40:1 flow turndown |
Line Sizes | 0.15-8 inch (4-200mm) |
Liner Materials | ETFE, PTFE, and PFA |
Electrode Materials | 316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium Consult factory for additional material options |
Flange Ratings |
ASME B16.5 Class 150-300 DIN PN 10-40 |
Interchangeability |
Compatible with all E-Series transmitters Compatible with Legacy transmitters
|
The flangeless design of the 8711 wafer sensor make it an economical, compact, and lightweight alternative to flanged magnetic flowmeters. Alignment rings provided with every 8711 center the sensor in the process line and make installation easier.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Benefits
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Applications The 8700 Magnetic Flowmeter Systems provide obstructionless flow measurement that is ideal for metering any conductive fluid. A wide choice of construction materials provides compatibility with virtually all applications, from highly corrosive liquids to fibrous slurries often considered difficult to measure with other devices. Rosemount Magnetic Flowmeters offer the benefit of measuring flow in a package virtually unaffected by density, temperature, pressure, and viscosity change. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability With a wide range of liner and electrode materials available, the Rosemount 8700 Series Magnetic Flowmeter family is suitable for virtually any conductive liquid application. Rosemount Magnetic Flowmeters offer the benefit of measuring flow in a package unaffected by density, temperature, pressure, and viscosity change. Step 1: Flow Sensor Type
Step 2: Liner Material Selection
Step 3: Electrode Type and Material Selection
Step 4: Transmitter Selection
Step 5: Diagnostics and Enhanced Features
|
DOWNLOADS
Product Data Sheet Rosemount 8700 Series Magnetic Flowmeter Systems
Technical Data Sheet Magnetic Flowmeter Material Selection Guide