Technical characteristics
	• Flow rate up to:
	- 64 l/h for MAXROY® D105
	- 410 l/h for MAXROY® A105
	- 420 l/h for MAXROY® B105
	- 1100 l/h for MAXROY® B145
	• Pressure up to:
	- 10 bar for MAXROY® A105 and B145
	- 28 bar for MAXROY® B105 and D105
	• Maximum temperature of pumped liquid:
	- +90 °C for metallic liquid end
	- +50 °C for plastic liquid end
	• Adjustment of flow rate while running or stopped: from 0 to 100%
	• Accuracy: ± 1% of rated flow from 10% to 100% stroke
	• Internal safety valve, normally set at the factory
	Optional relief valve setting
	• Suction lift: up to 2 m water save for "Viscous Liquids" version
	• Maximum suction pressure condition: 2 bar
	• Working life of the diaphragm can exceed 20,000 hours depending
	on the pumped fluid, working conditions and installation
	• Single or double diaphragm
	• Multiplexing available
	• Can comply with API 675
	• Explosion-proof version is in accordance with ATEX CE II 2 G/D c T4
	(plastic liquid end, please consult us)
	 
	Electrical characteristics of motors
	Standard motor data:
	• Supply: 230/400 V, 3-phase, 50 Hz or 260/460 V, 3-phase, 60 Hz
	• IM V1 mounting, FF130 flange, 14x30 mm shaft for
	MAXROY® A105, B145 and D105
	IM V1 mounting, FF165 flange, 19x40 mm or 24x50 mm shaft
	for MAXROY® B105
	• Protection: IP 55, tropicalized (90%)
	• Insulation: class F
	• Ambient temperature: -16 °C to +40 °C
	• Motor speed:
	- 1000 rpm for MAXROY® A105, B145 and D105
	- 1000 or 1500 rpm for MAXROY® B105
	• Motors are in accordance with national and international
	standards
	• Special or specific motors on request