From DN 25 to DN 1200 (1" to 48")
From DN 50 to DN 300 (1" to 12") (SITRANS F M MAG 8000 CT)
From DN 50 to DN 600 (2” to 24”) (SITRANS F M MAG 8000 Irrigation)
Accuracy
0.2% ± 2mm/s and 0.4% ± 2mm/s
0.8% ± 2.5 mm/s (SITRANS F M MAG 8000 Irrigation)
Input / output
2 passive outputs
Communication
IrDA: Standard integrated infrared communication interface with MODBUS RTU protocol
RS232 or RS485 serial interface with
MODBUS RTU
Encoder interface (for Itron 200 WP) with "Sensus protocol"
Optional GSM/GPRS Wireless Communication Module
Power supply
Internal or external battery pack
12-24 V AC/DC and 115-230 V AC
Operating pressure
Max. 16 bar (Max. 150 psi)
Max. 7 bar (Max. 101 psi) (SITRANS F M MAG 8000 Irrigation)
Ambient temperature
From -20 to 60 °C (-4 to 140 °F)
Medium temperature
From 0 to 70 °C (32 to 158 °F)
From 0.1 to 50 °C (32 to 122 °F) (SITRANS F M MAG 8000 CT)
Liner
EPDM
Ebonite hard rubber (SITRANS F M MAG 8000 Irrigation)
Electrodes
Hastelloy C 276
Stainless steel AISI 316 (SITRANS F M MAG 8000 Irrigation)
Enclosure
IP67 (NEMA 4)
IP68 (NEMA 6P)
Material
Transmitter:Stainless steel top housing (AISI 316)
and coated brass bottom.
Sensor: Carbon steel
Approvals
WRAS, KTW, DVGW 270, ACS, Belgaqua, NSF/ANSI Standard 61,
MID (EU), OIML R49, MCERTS Sira Certificate No. MC080137/00
NMI 10 for SITRANS F M MAG 8000 Irrigation (under preparation)
Description:
The SITRANS F M MAG 8000 program of battery-operated water meters gives you the flexibility to install a reliable water flow meter virtually anywhere without sacrificing accuracy or performance. No mains power is required. MAG 8000 complies with the custody transfer approvals MID and OIML R49 water meter standards and is specially engineered for stand-alone water applications such as abstraction, distribution network, revenue metering and irrigation
Application Examples: Abstraction and distribution network, Revenue and bulk metering and Irrigration
The SITRANS F M MAG 8000 program features a basic version for general water applications or an advanced version for more advanced functionality and information
An optional build-in GSM/GPRS Wireless Communication Module opens up for receiving logged flow measurement data via email, SMS and to OPC server – keeps the operator up-to-date regardless of location and makes it possible to change settings without visiting the site
The flowmeter can be combined with the energy calculatorSITRANS FUE950
Benefits:
Simple meter placement - floating chamber IP 68 (NEMA 6P) design ensures continuous filterless performance regardless of position or in-line piping stresses, even when buried underground
Low pressure loss - unrestricted flow tube ensures minimal pressure loss even at high flow rates and reduces overall network system pressure, helping to prevent leakage from burst pipes and excess stress placed on pumping stations
Zero maintenance – no moving parts and 10-year battery life
Bi-directional measurement - only one meter required for measurement in both directions
Installation requires 0D inlet to and outlet from the sensor - eliminating concerns about where the meter is installed
Intelligent meter – capable of leak detection, data logging and error self-detection
Remote capabilities – stay up-to-date on measurement data without having to visit the site through optional GSM/GPRS Wireless Communication Module