Home / Products / ANALYSERS / SENSOR / Turbimax CUS51D
Turbimax CUS51D

Sensor for turbidity and solids content

Turbimax CUS51D is a sensor for all wastewater treatment applications.

• Turbidity measurement in the outlet

• Solids content in sludge activation and recirculation

• Solids content in sludge treatment

• Filterable matter in outlet of WWTPs

 

Your benefits

• All sensor principles (90°, 135° and 4-beam pulsed light) are contained in the sensor head and enable optimum adaptation to the measuring task.

• The sensor is calibrated in the factory (on the basis of formazine). All selectable applications (e.g. activated sludge) are pre-calibrated, thereby enabling quick and easy commissioning.

• Standardized communication (Memosens technology) enables "plug and play".

• Intelligent sensor - all characteristics and calibration values are stored in the sensor.

• Customer calibrations with 1 to 5 points (max.) - can be performed in the lab or at place of installation.

 

Specifications

 

 

 

Application

Turbidity

0,000 to 4000 FNU

Display range up to 9999 FNU

Formazine

Solids content

CUS51D-**C1 :0 to 5 g/l

CUS51D-**D1 :

0 to 300 g/l

0 to 30 %

Kaolin, filterable matter

Solids content depending on the selected application (see list)

 

Temperature

–20 to 80 °C (–4 to 176 °F)

 

Process temperature range

–5 to 50 °C (23 to 122 °F)

Up to 80 °C (176 °F) for a short period of time (1 h)

 

Process pressure range

 

0.5 to 10 bar (7.3 to 145 psi) (abs.)

 

Minimum flow

 

No minimum flow required.

 

 

Ambient temperature range

 

–20 to 60 °C (–4 to 140 °F)

 

Storage temperature

 

–20 to 70 °C (–4 to 158 °F)

 

Degree of protection

 

IP 68 (1 m (3.3 ft) water column, 60 days, 1 mol/l KCl)

 

Electromagnetic

compatibility (EMC)

Interference emission and interference immunity as per

• EN 61326-1:2013

• EN 61326-2-3:2013

• NAMUR NE21: 2012

 

 

 

Download:
  • Datasheet
  • Operating Instructions