Digital combined pH/ORP sensor Memosens CPS16D

Memosens glass electrode for standard applications

Memosens CPS16D is the digital all-rounder for simultaneous pH and ORP measurement offering better process control and increased quality. The sensor features a dirt-repellent PTFE diaphragm for process and environment applications with long-term stable conditions. Thanks to Memosens digital technology, CPS16D combines maximum process and data integrity with simple operation. It resists corrosion and moisture, enables lab calibration and facilitates predictive maintenance.

Benefits

  • Simultaneous measurement of pH, ORP and rH values (in rH mode) for a better process overview
  • Additional platinum electrode enables constant monitoring of reference impedance and thus sensor quality
  • Robust and resistant to poisoning thanks to large PTFE ring diaphragm and reference with ion trap
  • Suitable for harsh applications: Process glass for highly alkaline media and pressure-stable up to 17 bar (246 psi)
  • Enables predictive maintenance due to storage of sensor and process-specific data
  • Reduced operating costs thanks to minimized process downtime and extended sensor lifetime

Field of application

  • Long-term monitoring or limit control in processes with stable process conditions:
    - Chemical processes
    - Pulp and paper industry
    - Power stations (e.g. flue gas cleaning)
    - Incinerator plants
    - Mining
    - Wastewater
  • Water treatment:
    - Drinking water
    - Cooling water
    - Well water

With ATEX and IEC approval for use in hazardous areas.

Features and specifications

Measuring principle

Glass electrode

Application

Standard applications in process and environment, long-term monitoring, processes with stable conditions, water treatment

Characteristic

Combination of pH and ORP electrode for standard applications in process technology and environmental engineering
Poison-resistant reference with ion trap

Measuring principle

Gel compact electrode with PTFE ring-diaphragm with ion trap
Pt-disc as additional ORP element
rH measurment and control of the reference impedance

Design

All shaft lengths with temperature sensor
Advanced gel technology
Digital electrode with Memosens technology

Material

Glass and PTFE

Dimension

Diameter: 12 mm (0.47 inch)
Shaft Lengths: 120, 225 and 360 mm
(4.72, 8.86 and 14.17 inch)

Process temperature

0 to 135 °C (32 to 275 °F)

Process pressure

1 to 17 bar (15 to 246 psi)

Temperature sensor

NTC 30KΩ

Connection

Inductive, digital connection head with Memosens technology

Ingres protection

IP68

 